Autoclave Feature
- Microcomputer control system for automatic check; imported Motorola sensor for precise control
With precise control, the temperature can be controlled within ± 0.5 during sterilizing
Friendly operation interface, simply and easy
B&D test, vacuum test, convenient for machine behave test
Automatically record of the time of sterilization beginning &end. Clean the inner pipe automatically for avoiding jam after every 100 times of cycles.
The dry time is adjustable according to your will
Omron button, work well for 100 thousands
The machine is dual-purpose, not only for instruments, but also for cotton, on dry condition
With a LCD display you can see the date and curve of sterilization process clearly
Adjustable date time & language mode according to your will
Adopt imported silicon tube, high pressure and high temperature resistant
Opened reservoir, convenient for cleaning, avoiding chloramphenicol alive
Alarmed automatically when the storage tank is empty and the waster tank is full so that you don’t need to worry for this problem
Water quality sensor can test the quality of distilled water, reduce the failure rate
One-piece chamber is made of imported 304 stainless steel
Safety valve ensure the chamber can release the pressure safely at emergency
Double doors locking-system, mechanical lock with electrical lock, the machine can’t open until the pressure turn 0
Multi-safety protection system, which can ensure the safety of the operator
Air-conditional heat removal system, prevent the machine from over-heating
Adopt the ABS plastic, whole model produce
Imported Italy water pump
Imported two-head vacuum pump with leather cup, vacuum more completely
The machine plane can adjust by adjustable pad, provide a gradience for free
Optional printer, with a internal USB module as standard collocation to record the sterilization process
Autoclave Prompt
1. Please place the sterilization on a plane place , which could adjust the height by adjusting foot pad
2. Please adopt distilled water to extend the service life
3. Don’t block the heat removal system on the surface of sterilization
4. Please put the instruments on the tray not touching one another allowing space for steam to pass through
5. Please empty the used water tank frequently. Usually it need empty when the clean water in the reservoir is empty.
6. Please ensure the door handle is closed tightly
7. Never try to open the chamber door if and when the pressure display doesn’t show “0.0”
8. Please cut off the power and cool down the auto clave before maintenance
9. Don’t drag the machine while moving
10. Power connection must be grounded properly
11. Must be provided enough power. (23L:2300VA/18L:1800VA)
12. While the outside temperature is too low, please pre-heating the machine without instruments for 30 minutes
before sterilize
Autoclave Parameters
- Voltage :AC 220V ±10%
- Frequency: 50/60Hz
- Wire plug : GB 3 cores/EN 3 cores
- Max Hp : 1800VA
- Electric current: 10A
- Physical Space: 22L/17L
- Class: European Class B standard
- Sterilizing temperature: 121℃,134℃
- Special sterilization : Kill active HV,HBV,BSE and spore
- Dry procedure: Strong vacuum drying, the residual humidity < 0.2%
- Display: LCD, multi-languages
- Test: Bowie& Dick, Leak
- Safety: Safety valve, Automatic check
- Sterilizing record: There is a micro-printer optional, and a standard USB connector optional for sterilizing record
- Water supply system : Two opened Reservoirs(3.5L fresh water and 5 liter waste water reservoirs), easy for sterilization and clean
- Water quality detection: Detect whether water quality meet the requirement
- Clean procedure: Automatic clean inside pipe and steam generator
- Instrument containers: 5 levels with 3 trays
- Chamber size: 249mm*450mm/249mm*355mm
- Net weight: 50Kg/47KG
Autoclave Maintenance
How to clean the water tank.
1. Please clean the autoclave water tank and waste water tank regularly. The process is the following:
1.1 Drain the water from the tanks, please see point.
2. Open the tank cover panel, you can use a screwdriver to loosen the five screws.
3. Lift the lid of the water tank cover
4. Lift the tank cover completely, the tank cover can be removed.
5. You can start cleaning the tank, you can use cotton and some alcohol or disinfectant to clean the tank wall, wash with distilled water, then empty the tank and dry. The filter net must then be removed for cleaning.
6. After cleaning the tank, fit the cover and tighten the screws.
Draining water from the machine. Draining the condenser water collector and the water tank.
Connect the water outlet with the non-connector tube end and the other end of the drain tube to a sink.
Then turn the drain knob to drain the water from the machine.
Caution: Maintenance must be carried out after the power has been cut off and the autoclave has cooled down.
Distilled water should be used. Instruments placed in the chamber must be cleaned.
As for some instruments with oil or impurities, we request that they be packed with the sterilization bag.
Autoclave Function
8.1 To enter the config mode: Press. STEP for 20s when not working.
Time: Ld Pressure 1 setting function mode.
8.2 Function setting with 7 options, press SELECT key, you can select 1-7-1 in cycle screen.
The 7 options are displayed as follows:
Option 1: year, shows “yer” press STEP or the increment button, press DRY
or the decrease key, select a numeric value.
Option 2: month, displays “nth” press STEP or the Increment button, press DRY
or the decrease key, select a numeric value.
Option 3: day, displays “day” press STEP or the increment button, press DRY
or the decrease key, select a numeric value.
Option 4: hour, show “hour” press STEP or the increment button, press DRY
or the decrease key, select a numeric value.
Option 5: minute, displays “nin” press STEP or the increment button, press DRY
or the decrease key, select a numeric value.
Option 6 Print, display “Pvt”, press STEP key, choose cycle between on and
off, with or without printing.
Option 7 Exit, display “Eit”, please press START / STOP to save and exit setup.
Option 8 Modification of the sterilization time, displays “S-T” when setting this option, the sterilization time (SP) increases to the original range.
There are three types of adjustable ranges. The first increases by 1 minute, the second is increased by 2 minutes, and the third is increased by 3 minutes.
Option 9: Automatic modification of temperature data, display “DP”, By setting this option you can adjust the temperature more or less than 2C-3C in order to satisfy your request. However, the configuration is suggested under the recommendation of a technician.
Press SELECT key after installation, you will return to option 1. At this time, you need to press STEP key for 3 seconds in option 7. Then you can start option and option 8 setting. Otherwise, the cycle can only be started between option 1 and option 7.
Caution: If any function setting is changed by pressing the key unintentionally, please turn the device off and on again. Configuration will be exited. In this case, the function will not be affected by it.
Autoclave Problem Resolution
There are sounds during ventilation or drying. This means that the condensation collector is full. You must drain the water from the collector.
2. Hissing of the chamber door. (The solution to this problem is in the door settings section)
3.During the cycle you hear heavy steam knocks and leaks from the chamber door, the error code shows E6.
Please check if the door knob is properly closed. If there are steam leaks at the beginning of the cycle, it is necessary to change the seal according to the instructions on page 18.
4.When the cycle ends, there are drops of water on the instruments.
You can correct the problem:
1). Please check the drain filter.
2). Reduce the load of the instruments in the chamber.
3). You can wait a while at the end of the Ed cycle for a better drying result.
The autoclave will continue to heat the chamber until the door is opened.
Important information
1.The autoclave must be installed level.
2.When operating at a height greater than 500 meters, the machine must be reprogrammed.
3.Distilled water should be used to extend the life of the machine.
4. Radiation openings on the machine must not be blocked or covered.
5.The instruments should be placed on the tray leaving space between them allowing the steam to pass through.
6.The condensate collector must be emptied from time to time. It should be emptied when filling the water tank. (The drainage of the collector can be followed according to point 9.2)
7.The tank door handle should be turned to its locked position.
8.Never try to open the chamber door before pressure shows. “0.0” .
9.To avoid burns, turn off the machine and allow it to cool down before replacing the seal.
10.Do not move the machine when it is in motion.
11. The power supply must be properly grounded.
12. Sufficient power must be provided. (1800VA)
13.When the outside temperature is lower, please heat the machine without the instruments for 30 minutes before sterilizing.